Plugin: Novatek Touchscreen
Introduction
This plugin allows updating Novatek touchscreen controllers. Devices are enumerated using HIDRAW.
Firmware Format
The daemon will decompress the cabinet archive and extract the firmware blob.
This plugin expects a raw binary payload with an end flag of NVT and a maximum size of 320KB.
This plugin supports the following protocol ID:
tw.com.novatek.ts
GUID Generation
These devices use the standard DeviceInstanceId values, e.g.
HIDRAW\VEN_0603&DEV_F203
An additional instance ID is added which corresponds to the PID read from flash:
HIDRAW\VEN_0603&PJID_60AA
Update Behavior
The device is updated after switching into idle mode, where the touchscreen is nonfunctional. The firmware is written using GCM commands with erase, program, and verify, and the device is reset back to normal runtime mode on success.
Vendor ID Security
The vendor ID is set from the HID vendor, e.g. HIDRAW:0x0603
External Interface Access
This plugin requires ioctl access to HIDIOCSFEATURE and HIDIOCGFEATURE and
read/write access to /dev/hidraw.